H O W   T H E   E X P E R I M E N T A L   D I A L   S Y S T E M   W O R K S :
*****************************************************************************
RELAIS (RELAYS) and their associated CONTACTS are shown in the SAME COLOR.
where:   r = "rest"     Contact is closed when the relais is not activated.
         a = "active"   Contact is closed when the relais is activated.
SSW(r12) opens, when the SSW ( = "Schritt-Schalt-Werk" ) reaches POSITION 12.
SSW(r02) opens, when the SSW ( = "Step-Switch-Work" ) is in motion.
SSW(r01) ( with RR(r) & DR(a), the ACTIVE TIME DELAY of DR-Relais )
         ensure that NO USER CONTACT is made when the SSW is in motion.
The DIAGRAM shows an IDLE STATE with USER "3" SELECTED.  To change the user,
first a RESET is necessary.  Pressing ( and releasing ) the RESET Button
activates the RESET-Relais, because SSW(r12) is closed.  With RR(a1) it holds
its own activation and with RR(a2) it starts the PULSAR-Relais.  The PULSAR-
Relais activates with PR(a) the SSW until the SSW reaches position 12 and
opens SSW(r12).  This deactivates the RESET Relais and opens RR(a1) & RR(a2).
This stops the PULSAR Relais.  The RESET Position is found.
Selecting (e.g.) a new USER "6" by DIALING the "6" lets the SSW move 6 steps
to position "6". After a DELAY TIME contact DR(a) connects the USER "6" ...
R E M A R K  (DR) DELAY-RELAIS:  S1 = T1 = ON-Delay;  ( S2 = T2 = OFF-Delay )
See ... "HOW THE PULSAR IS WORKING" ...  in the chapter COUNTERS.
                 HOW TO POWER THE EXPERIMENT with 2x24=48 Volt ?
                          Back to the Photo with the Building Blocks ...
IN  A  REAL  R E L A Y  D I A L  S Y S T E M  from  1950  (eg. DEUTSCHE POST)
"SSW"s were connected in a tree-like structure.  When customer A picks up his
hand set, the 1st SSW connects customer A with the  (FERNMELDEAMT  in German)
SWITCHING STATION  and customer A gets a  DIAL TONE.  When  customer A dials,
every digit activates a  SSW in sequence  until the selected  customer  B  is
contacted.  Pulses from the  SWITCHING STATION  activates the  RINGER  in B's
station.  Customer B picks up his hand set and the connection between A and B
is established.  When the conversation is finished,  A and B  hang up and all
SSWs are RESET ...